BLCVF - 1620 ANTI SPATTER

  • MSDS: BLCVF
  • Manufacturer: THERMACOTE WELCO
  • Product Name: 1620 ANTI SPATTER
  • National Stock Number: 6850-00N019436
Product Identification

Product ID:1620 ANTI SPATTER
MSDS Date:06/26/1990
FSC:6850
NIIN:00N019436
MSDS Number: BLCVF

Responsible Party
THERMACOTE WELCO
HWY 161 SOUTH YORK ROAD
KINGS MOUNTAIN, NC 28086
US

Emergency Phone: 704-739-6421

Info Phone: 704-739-6421

Cage: 0AES5

Contractor
THERMACOTE WELCO CO
KINGS MOUNTAIN, NC 28086 US

Cage: 0AES5

Ingredients

METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 73-84%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 17%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


&/OR TRANSFER OF CHLORINATES. NO SMKG IN AREA OF

RTECS: 9999999ZZ


OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION

RTECS: 9999999ZZ


ADD FULL LENGTH FACESHIELD TO GOGGLES .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EXCESSIVE INHALATION &
INGESTION MAY PRODUCE SYMPTOMS OF LIGHT HEADEDNESS TO
UNCONSCIOUSNESS TO DEATH. EXPOSURE OF SKIN & EYE MAY PRODUCE
IRRITATION. CHRONIC: HEADACHE, FATIGUE, NAUSEA, DEPRESS ION &
VISUAL DISTURBANCE. CHLOROCARBON MATLS HAVE PRDCED SENSIT OF THE
MYOCARDIUM TO EPINEPHRINE IN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: CLASS 2 (NTP); CLASS
2B (IARC).
Effects of Overexposure:HLTH HAZ: LAB ANIMALS & MAY HAVE A SIMILAR EFT
IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCA RBONS . PRLNG CONT W/HIGH CONC
CAN LEAD TO SERIOUS KIDNEY/ LIVER DAMAGE.
Medical Cond Aggravated by Exposure:PRE-EXISTING LIVER/BLOOD DISORDERS
AGGRAVATED BY EXPOS TO MATL. PERSONS W/HEART CNDTNS MAY BE
SUSCEPTIBLE TO ARRHYTHMIAS AS EXPOSED TO MATL. REPORTS ASSOC RPTD
OCCUP OVEREXP TO SOLV W/ PERM (SUPP DATA

First Aid

First Aid:EYES: FLUSH W/WATER FOR A MINIMUM OF 15 MINUTES. SKIN: WASH
W/SOAP & WATER. INGEST: DRINK WATER, INDUCE VOMITING. INHAL: REMOVE
TO FRESH AIR. CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, CO2, HALON, FOAM, OR WATER SPRAY IS
RECOMMENDED.
Fire Fighting Procedures:NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT SHOULD BE PROVIDED TO FIRE FIGHTERS.
Unusual Fire/Explosion Hazard:STORAGE CONTRS EXPOSED TO FIRE SHLD BE
KEPT COOL. AT HIGH TEMPS, OVER-PRESSURIZATION OF CONTR CAN RESULT
IN FIRE. VAPS ARE HEAVIER THAN AIR & MAY (SUPP DATA)

Accidental Release

Spill Release Procedures:SPILLS SHLD BE SOAKED UP W/ABSORBENT. AREA
THEN BE FLUSHED W/WATER. ALL REINSATE WILL BE CONTAINERIZED &
LABELED. SPILLS ON AREAS THAT ARE NOT PAVEMENT CAN BE HANDLED BY
REMOVING THE AFFECTED SOILS. E PA REPORTABLE QUANTITY IS 1000 LBS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE CONTRS IN A COLD, DRY, WELL VENT
AREA AWAY FROM HEAT & ALL SOURCES OF IGNITION. KEEP CONTRS CLOSED.
KEEP AWAY FROM INCOMPATIBLE MATERIALS.
Other Precautions:DO NOT ENTER CONFINED SPACES SUCH AS TANKS OR PITS
W/O FOLLOWING PROPER ENTRY PROCS SUCH AS ASTM D-4276. USE OF RESP
PROT ADVISED WHEN CONCS EXCEED THE ESTABLISHED EXPOS LIMITS. WASH
THORO. DO NOT WEA R CONTAM CLTHG. GOOD PERSONAL(SUPP DATA)

Exposure Controls

Respiratory Protection:NONE DURING NORMAL USE. IF NECESSARY, USE NIOSH/
MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST - SUFFICIENT TO MAINTAIN TLV.
Protective Gloves:POLYFLUORINATED POLYETHYLENE SUGGESTED.
Eye Protection:CHEMICAL WORKERS GOGGLES. (ING 5)
Work Hygienic Practices:WASH THOROUGHLY. DO NOT WEAR CONTAM CLTHG. GOOD
PERSONAL HYGIENE ADVISED.
Supplemental Safety and Health
EXPLO HAZ: ACCUMULATE IN LOW AREAS. THERMAL DECOMP PRODS MAY INCLUDE
HCL & PHOSGENE . MED CNDTNS: BRAIN/NERVS SYS DMG. INTENTIONAL
MISUSE MAY BE HARMFUL/FATAL. OTHER PREC: HYGIENE ADVISED. EMPTY
CONTRS & RESIDUE ARE DANGEROUS. DISPOSE OF IN SAFE MANNER I/A/W
REGS. ALUMINUM CONTRS NOT ADVISED FOR STORAGE (ING 3)

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:104F,40C
Vapor Pres:390
Vapor Density:2.9
Spec Gravity:1.32
Evaporation Rate & Reference:14.5 (BUTYL ACETATE=1)
Solubility in Water:1.3% BY WEIGHT
Appearance and Odor:CLEAR, COLORLESS LIQUID, CHARACTERISTIC ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES & ALKALI METALS.
Stability Condition to Avoid:HIGH PRESSURE IN ALUMINUM SYSTEMS. AVOID
OPEN FLAMES OR ELECTRICAL ARCS.
Hazardous Decomposition Products:HYDROGEN CHLORIDE AND TRACES OF
PHOSGENE.

Disposal

Waste Disposal Methods:THE MATLS RESULTING FROM CLEAN-UP OPERATIONS MAY
BE HAZARDOUS WASTES, AND THEREFORE SUBJECT TO LOCAL, STATE, AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.